Chapter 73 Additional Commands
Ethernet Switch CLI Reference Guide
259
This example displays run-time SFP (Small Form Facter Pluggable) parameters on ports 9 (the
first SFP port 0, with an SFP transceiver installed) and 10 (the second SFP port 1, no SFP
transceiver installed) on the
Switch. You can also see the alarm and warning threasholds for
temperature, voltage, transmission bias, transmission and receiving power as shown.
This example runs an internal loopback test on ports 3-6.
This example displays route information to an Ethernet device with IP address
192.168.1.100.
sysname# show sfp 9-10
SFP : 0
Part Number : SFP-SX-DDM
Series Number : S081113001132
Revision : V1.0
Transceiver : 1000BASE-SX
Temperature(C) Alarm(80.00 ~ 0.00), Warning(75.00 ~ 5.00), Current(38.00)
Voltage(V) Alarm(3.50 ~ 3.10), Warning(3.45 ~ 3.15), Current(3.37)
Tx Bias(mA) Alarm(100.05 ~ 1.00), Warning(90.04 ~ 2.00), Current(5.25)
Tx Power(dBm) Alarm(-2.99 ~ -8.98), Warning(-3.49 ~ -8.48), Current(-6.05)
Rx Power(dBm) Alarm(-2.99 ~ -18.01), Warning(-3.49 ~ -17.39), Current(-4.24)
SFP : 1
Not Available
sysname# test interface port-channel 3-6
Testing internal loopback on port 3 :Passed!
Ethernet Port 3 Test ok.
Testing internal loopback on port 4 :Passed!
Ethernet Port 4 Test ok.
Testing internal loopback on port 5 :Passed!
Ethernet Port 5 Test ok.
Testing internal loopback on port 6 :Passed!
Ethernet Port 6 Test ok.
sysname> traceroute 192.168.1.100
traceroute to 192.168.1.100, 30 hops max, 40 byte packet
1:192.168.1.100 (10 ms) (10 ms) (0 ms)
traceroute done:
sysname>