Chapter 44 Alarm
IES-1248-51V User’s Guide
311
dsl (5003)ad_perf_lof_thresh info V The number of times a Loss Of
Frame has occurred within 15
minutes for the ATU (C or R) has
reached the threshold.
dsl (5004)ad_perf_los_thresh info V The number of times a Loss Of
Signal has occurred within 15
minutes for the ATU (C or R) has
reached the threshold.
dsl (5005)ad_perf_lop_thresh info V The number of times a Loss Of
Power has occurred within 15
minutes for the ATU (C or R) has
reached the threshold.
dsl (5006)ad_perf_es_thresh info V The number of error seconds within
15 minutes for the ATU (C or R) has
reached the threshold.
dsl (5007)ad_perf_ses_thresh info V The number of severely errored
seconds within 15 minutes for the
ATU (C or R) has reached the
threshold.
dsl (5008)ad_perf_uas_thresh info V The number of unavailable error
seconds within 15 minutes for the
ATU (C or R) has reached the
threshold.
dsl (5009)ad_atuc_loftrap minor A Loss Of Frame was detected on
the ATUC.
dsl (5010)ad_atuc_lostrap minor A Loss Of Signal was detected on
the ATUC.
dsl (5011)ad_atur_loftrap minor A Loss Of Frame was detected on
the ATUR.
dsl (5012)ad_atur_lostrap minor A Loss Of Signal was detected on
the ATUR.
dsl (5013)ad_atur_lprtrap minor A Loss of Power was detected on the
ATUR.
eqpt (10000)vol_err critical The input voltage (Vn) is lower than
the low-threshold or higher than the
high-threshold.
eqpt (10001)temp_err critical The temperature (Tn) is higher than
the high-threshold or lower than the
low-threshold.
eqpt (10002)fan_err critical The fan RPM ‘n’ is over the high-
threshold or lower than the low-
threshold.
eqpt (10003)hw_rtc_fail critical The Real Time Chip diagnosis test
failed.
eqpt (10004)hw_mon_fail critical The hardware monitor diagnosis
test failed.
eqpt (10005)cold_start info System cold-start.
Table 106 Alarm Descriptions (continued)